BMR Review Batch record checking
Templates / BMR/T/XX123/123-00

XXXXX Tablets 100 mg: compression & coating dispensing

In use for new uploads · saved 25 Nov 2026, 12:18 pm by System (from blank BMR)

Last change: Completed from the blank BMR (all 17 pages): added persons list, filter ΔP limits, coating issue and signatures, machine setting times, width limits, RHS dimensions, min/max checks, page-number continuity and reading notes from the filled example.

112 rules in 11 sections
Header · Page header (every page)3 rules
  • Page header must have at least 17 rowsCritical
  • Page header: Batch no. in header must match Batch no.Minor
  • Page numbers must be continuous on all pages (1 to N, no gaps or repeats)Major
p1 · Batch identity and sign-off9 rules
  • p1Batch no. is requiredCritical
  • p1Manufacturing date is requiredMajor
  • p1Expiry date is requiredMajor
  • p1Expiry date must be after Manufacturing dateCritical
  • p1Batch size = Batch size (numbers) × 700 ÷ 1000000Major
  • p1Input material eq. tablets = Input material × 1000000 ÷ 700 (± 0.5%)Major
  • p1Manufacturing completed on must be on or after Manufacturing commenced onMajor
  • p1Filled BMR reviewed by Head MF must be signedCritical
  • p1Filled BMR approved by Head QA must be signedCritical
2.0 · Persons involved in manufacturing2 rules
  • p4Persons involved must have at least 1 rowsMinor
  • p4Persons involved: Signature must be signedMinor
3.0 · Quantity of blend received10 rules
  • p6Blend received: Net weight = Blend received: Gross weight − Blend received: Tare weight (± 0.005)Major
  • p6Total gross weight = total of Blend received: Gross weightMajor
  • p6Total tare weight = total of Blend received: Tare weightMajor
  • p6Total net weight = total of Blend received: Net weightMajor
  • p6Total net weight = Batch size (± 5%)Critical
  • p6Blend received: Checked by (MF) date must be on or before Blend received: Verified by (IPQA) dateMajor
  • p6Balance check: verified by (IPQA) must be signedMajor
  • p6Batch no. of common blend must match Input batch numberMajor
  • p6Blend received: Verified by (IPQA) must be signedMajor
  • p6Weighing balance ID no. is requiredMinor
4.0 · Coating material: master formula and dispensing16 rules
  • p7Coating quantity (master formula) = Opadry Pink per tablet × Batch size (numbers) × (1 + Coating overage ÷ 100) ÷ 1000000 (± 0.002)Major
  • p8Dispensing line clearance date must be on or before Manufacturing commenced onMajor
  • p8Dispensing area cleaning verified by IPQA must be signedMajor
  • p8Dispensing booth ΔP must be at least 1 mm WCMajor
  • p8Dispensing room temperature must be at most 25 °CMajor
  • p8Dispensing room RH must be at most 55 %Major
  • p8Dispensing: previous product is requiredMajor
  • p8Intermediate filter ΔP must be 3–7 mm WCMajor
  • p8HEPA filter ΔP must be 10–25 mm WCMajor
  • p8Dispensing room readings verified by IPQA must be signedMinor
  • p9Coating standard quantity must be within 0.002 of Coating quantity (master formula)Major
  • p9Coating issued net quantity must be at least Coating standard quantityMinor
  • p9Coating issued net quantity = Coating issued gross weight − Coating issued tare weight (± 0.005)Major
  • p9Coating material A.R. no. is requiredMajor
  • p9Dispensing done by WH must be signedMajor
  • p9Dispensing checked by QA must be signedMajor
5.1 · Compression line clearance10 rules
  • p10Compression line clearance date & time is requiredMajor
  • p10Compression area cleaning verified by IPQA must be signedMajor
  • p10ΔP MAL vs corridor must be at least 10 PaCritical
  • p10ΔP MAL vs manufacturing cubicle must be at least 10 PaCritical
  • p10ΔP PAL vs corridor must be at least 10 PaCritical
  • p10ΔP PAL vs cubicle must be at least 10 PaCritical
  • p10Compression room temperature must be at most 25 °CMajor
  • p10Compression room RH must be at most 55 %Major
  • p10Compression: previous product is requiredMajor
  • p10Compression room readings verified by IPQA must be signedMinor
5.3 · Metal detector challenge test6 rules
  • p11Metal detector test piece ID is requiredMinor
  • p11Total metal detector rejects is requiredMinor
  • p11Metal detector challenge: Date & time readings must be at most 240 minutes apartMajor
  • p11Metal detector challenge must have at least 3 rowsMajor
  • p11Metal detector challenge: Ferrous 0.15 mm must be "Complies"Critical
  • p11Metal detector challenge: Verified by (IPQA) must be signedMinor
5.4.1 · Compression machine setting8 rules
  • p12Upper punch observed must be "16.00 × 9.50 mm oval"Critical
  • p12Lower punch observed must be "16.00 × 9.50 mm oval"Major
  • p12Die observed must be "16.00 × 9.50 mm oval"Critical
  • p12Die punch ID is requiredMajor
  • p12Punch and die checked by must be signedMajor
  • p12Machine setting verified by IPQA must be signedMinor
  • p12Machine setting to (date & time) must be on or after Machine setting from (date & time)Minor
  • p12All signatures on page 12 must be signed and datedMajor
5.4.2 LHS · In-process checks, LHS21 rules
  • p13LHS appearance observation (row 3) is requiredMinor
  • p13LHS dimensions: Length must be 15.8–16.2 mmMajor
  • p13LHS appearance & dimensions checked by IPQA must be signedMajor
  • p13LHS dimensions: Width must be 9.3–9.7 mmMajor
  • p14LHS thickness checked by IPQA must be signedMinor
  • p14LHS group weight of 20 must be 13.3–14.7 gMajor
  • p14LHS average weight must be 665–735 mgCritical
  • p14LHS average weight = LHS group weight of 20 × 1000 ÷ 20 (± 1)Major
  • p14LHS group weight of 20 unit must be gMinor
  • p14LHS average weight unit must be mgMinor
  • p14LHS uniformity of weight: Tablet weight must be 665–735 mgCritical
  • p14LHS uniformity of weight must have at least 20 rowsMajor
  • p14LHS hardness: Hardness must be 10–18 kpMajor
  • p14LHS max hardness (recorded) = max of LHS hardness: Hardness (± 0)Minor
  • p14LHS friability = (LHS friability weight before (A) − LHS friability weight after (B)) ÷ LHS friability weight before (A) × 100Major
  • p14LHS friability must be 0–1 %Major
  • p14LHS thickness: Thickness must be 5.5–6.5 mmMajor
  • p14LHS disintegration time must be at most 60 minCritical
  • p14LHS min hardness (recorded) = min of LHS hardness: Hardness (± 0)Minor
  • p14LHS min thickness (recorded) = min of LHS thickness: Thickness (± 0.005)Minor
  • p14LHS max thickness (recorded) = max of LHS thickness: Thickness (± 0.005)Minor
5.4.2 RHS · In-process checks, RHS23 rules
  • p14LHS machine speed must be within 10 of RHS machine speedMinor
  • p15RHS dimensions: Length must be 15.8–16.2 mmMajor
  • p15RHS dimensions: Width must be 9.3–9.7 mmMajor
  • p15RHS appearance & dimensions checked by IPQA must be signedMajor
  • p16RHS group weight of 20 must be 13.3–14.7 gMajor
  • p16RHS average weight must be 665–735 mgMajor
  • p16RHS average weight = RHS group weight of 20 × 1000 ÷ 20 (± 1)Major
  • p16RHS group weight of 20 unit must be gMinor
  • p16RHS average weight unit must be mgMinor
  • p16RHS uniformity of weight: Tablet weight must be 665–735 mgMajor
  • p16RHS uniformity of weight must have at least 20 rowsMajor
  • p16RHS hardness: Hardness must be 10–18 kpMajor
  • p16RHS max hardness (recorded) = max of RHS hardness: Hardness (± 0)Minor
  • p16RHS friability = (RHS friability weight before (A) − RHS friability weight after (B)) ÷ RHS friability weight before (A) × 100Major
  • p16RHS friability must be 0–1 %Major
  • p16RHS thickness: Thickness must be 5.5–6.5 mmMajor
  • p16RHS disintegration time must be at most 60 minCritical
  • p16RHS hardness checked by IPQA must be signedMinor
  • p16RHS DT checked by MF must be signedMinor
  • p16Tablets used for initial parameter checking is requiredMinor
  • p16RHS min hardness (recorded) = min of RHS hardness: Hardness (± 0)Minor
  • p16RHS min thickness (recorded) = min of RHS thickness: Thickness (± 0.005)Minor
  • p16RHS max thickness (recorded) = max of RHS thickness: Thickness (± 0.005)Minor
5.4.3 · Environmental conditions4 rules
  • p17Environmental conditions: Temperature must be at most 25 °CMajor
  • p17Environmental conditions: Relative humidity must be at most 55 %Major
  • p17Environmental conditions: Date & time readings must be at most 120 minutes apartMajor
  • p17Environmental conditions: Checked by IPQA must be signedMinor
Reading notes for the AIhow this form is filled in, taken from a filled example

How this form (ABC/123/A/01-04, 17 pages) is filled in, learned from a filled example: - Every page repeats the header; the batch no. is handwritten there and "Page No. x of 17" is printed. Read the printed page number into the page header table for every page. - Page 1: Mfg/Expiry dates are often month-year only ("FEB 2026"). Commenced/Completed have a date and a 24-hour time. - Month names are written loosely by hand (e.g. "FBB" for FEB, "3AN" for JAN). Return the month that is clearly meant, and give confidence of 0.75 or lower. - Sign & Date boxes hold initials or a scribble with a handwritten date underneath; one signature often spans several rows of a table. Report the signature as "present" for each row it covers and read the date into the matching date field. - Unused table rows are cancelled with one long diagonal line; those rows have no values and must not be returned. - A star (*) beside a value with the footnote "WRONG ENTRY CORRECTED" means the value was struck through and rewritten: return the new value, mark it corrected and describe what was struck. - Page 4–5: list of persons (name, employee code, signature); count the filled rows. - Page 6: blend containers table with gross, tare and net weight per row and a total row; the MF and IPQA dates may differ per row. - Page 8: observation values are written in the "Observation" column (ΔP 1.2, filter 5, HEPA 15.2, °C 23.6, RH 50.1 style decimals). - Page 9: the standard quantity 7.223 kg is printed, not handwritten; read the handwritten gross, tare and net issued. - Page 11: metal detector checks are rows with date, time, a ✓ in LHS/RHS (NA when only one side is used) and "Complies" per test piece. - Page 12: punch and die observations are short handwritten texts (size, shape, embossing) next to the printed standard "16.00 X 9.50mm oval". - Pages 13 and 15: appearance is a grid of ticks; length and width are grids of 9 readings per row read left to right, top to bottom (about 37 readings each). Number table rows in that order. - Pages 14 and 16: uniformity of weight is a 5×4 grid of 20 weights; hardness and thickness are 5×2 grids of 10 values, followed by handwritten Min/Max values. - Page 17: environment readings are rows of date, time, temperature, RH and two signatures with dates. - Stray pen marks can join digits (e.g. "69.62" where 9.62 is meant); keep what is written but give low confidence.

Fields read from the BMR134 fields